NT200
Contamination and Clearance CheckPoint: Area
TM
PHYSICAL CHARACTERISTICS
Detector: ●
Permanently lled and sealed proportional detector (Ar, CO ○
2
)
Active window diameter: 44 mm (1.73 in)
○
Normal operating voltage: 1475V ○
Plate length: approx. 100V ○
Detector’s life length at working voltage: 10E11 pulses ○
Ef ciency (2p geometry): ○
60
- Co: 32%
241
- Am: 30%
Background count rate:
○
0.1 μSv/h: < 0.5 CPS -
100 μSv/h: < 5 CPS -
Computer unit: ●
PC-104 form factor with 486 compatible processor ○
Memory card slot (MMC) for the update of storage programs ○
data transfert
2 RS-232 serial ports
○
External keyboard port ○
Display: ●
Resolution: 256 x 64 pixels ○
Display angle: almost 180° ○
CFL type white background light ○
screen saver in standby mode for increasing the CFL tube’s ○
life (picture of the measurement display)
ELECTRICAL CHARACTERISTICS
Standard model: 90-264 V AC, 47-440 Hz ●
DC model: 10-36 V DC ●
The NT200 complies with the EC standard. ●
MECHANICAL CHARACTERISTICS
Width: 186 mm (7.32 in) ●
Depth: 260 mm (10.23 in) ●
Height: 260 mm (10.23 in) ●
Lead shield thickness: 50 mm (1.97 in) ●
Total weight: 56 kg (123 lb) ●
The stainless steel sample holder can easily be ●
removed and decontaminated
The slide slot is coated with low friction PTFE for
●
smooth action
Stainless steel structure
●
OPTIONS
Keyboard and memory card option: the operator can add ●
comments for each sample, save it on the memory card and
then transfer it on his of ce PC
DC option: powered from 10-36V dc. Suitable for portable
●
use on trolleys or in cars/trucks
PCMCIA ash card reader
●
www.mirion.com
144703EN-B
The NT200 can also measure paper fi lters samples from an air-sampling
pump. The operator can select between four preset air volumes. The
result is displayed in Bq/m³.
The NT200 calibration is done
very easily with an automated
procedure.The activity of the
reference source, the measuring
time and the step high voltage
for the plates must be selected.
The NT200 automatically selects
the start and stop high voltage
and computes the detector res-
ponse curve which is displayed
in real time on the screen.
1 Nutronic trademark